•Error 25 - Alarm switcher running

100 en

LTC 8600 LTC 8800 Series

Error 25 - Alarm switcher running

Alarm video may only be acknowledged if the alarm switcher is not running; press [HOLD] to stop the switcher.

Error 50 - SEQUENCE not available

The user tried to load a switcher sequence that does not exist. This is a good way to tell from the keyboard which sequence numbers are unused when desir- ing to add one.

Error 51 - SEQUENCE request

A request was made to load an ABSOLUTE type sequence without the keyboard being on one of the monitors in that sequence. Because inadvertent loading of monitors should be avoided, the user is required to switch his keyboard to one of the monitors used by the sequence. The PROGRAM mode may be used to review what monitors are used in the sequence.

Error 52 - SEQUENCE request

A request was made to load a RELATIVE type sequence on too high of a monitor number; the monitors used by the sequence would extend past the highest monitor. Try switching to a lower monitor number before Loading the sequence.

Error 53 - Switcher empty

The user has tried to control a sequence using the NEXT, PREV, RUN, or HOLD keys without there being a sequence loaded.

Error 55 - SEQUENCE priority

The switcher sequence being requested or cleared requires monitors that are in use by a user of equal or higher priority. Contact a user with higher priority or have the system administrator clear the monitors in question.

Error 56 - SEQUENCE request

The user has tried to load a sequence that is being edited in the PROGRAM mode. Once editing is completed, the sequence may be loaded.

Error 58 - SEQUENCE request

The sequence being requested is a relative sequence, and the user is only allowed access to absolute sequences.

Error 60 - PROGRAM request

The user has tried to program a sequence that is currently running. The sequence must first be stopped before any editing can be performed.

Error 62 - PROGRAM request

The user has tried to program a new sequence when the system is out of sequence memory space. Delete unused sequences and then program the new sequence.

Error 63 - PROGRAM request

Some other user is already programming a sequence on this monitor.

Error 70 - Monitor not allocated to alarm monitor group

This monitor can not be used for alarm operations; it has not been designated as alarm-capable by the system programmer.

Error 71 - Step monitor required

A group of alarm monitors may not have an armed Review (display) monitor without having armed Step (sequence) monitors.

Error 78 - Must enter alarm number

A specific alarm number must be entered when arming or disarming an alarm.