Bosch Appliances LTC 8800, LTC 8600 Baud Rate, 115200, Stop Bits, Data Bits, Parity, None

Models: LTC 8600 LTC 8800

1 126
Download 126 pages 39.22 Kb
Page 41
Image 41
Baud Rate

LTC 8600 LTC 8800 Series

en 35

 

 

1.If using an Allegiant software package, attach the PC security key provided with the software to an available port on the computer.

The supplied interconnect cable utilizes a custom pinout. If it ever becomes necessary to replace the cable, it can be ordered separately using part number: LTC 8506/00. Alternatively, a cable can be configured using the information found in the Appendix Section of this manual.

2.Attach one end of the supplied RS-232 interface cable to the main Allegiant CPU bay connector marked Console (or another port that has been configured to operate as a Console port).

3.Attach the other end of the cable to an available serial port (COMM PORT 1 or COMM PORT 2) on the rear of the computer.

4.Apply power to the computer and allow it to boot up its operating system before inserting the software disc.

5.Refer to the applicable Allegiant software manual for complete programming instructions.

6.The communication settings of the PC must match those of the Allegiant. The Allegiant communication settings can be changed using Keyboard User Func- tion 30 (described later in this manual), or may have been previously set using the Master Control Software. The factory default values are as follows:

Baud Rate

115200

 

 

Stop Bits

1

 

 

Data Bits

8

 

 

Parity

None

 

 

F.01U.127.393 2.0 2009.03

Instruction Manual

Bosch Security Systems, Inc.

Page 41
Image 41
Bosch Appliances LTC 8800, LTC 8600 instruction manual Baud Rate, 115200, Stop Bits, Data Bits, Parity, None