LTC 8600 LTC 8800 Series | en 33 |
|
|
8.6.3LTC 8802 Series Monitor Expansion Bay Data Connections
The LTC 8802 Series Monitor Expansion Bay is supplied with a 1 m (3 ft) data com- munication interconnect cable. Install this cable between the Comm1 port on the LTC 8801 Series Main CPU bay, and the Comm1 port on the LTC 8802 Series Moni- tor Expansion Bay.
8.6.4Monitor Output Video Connections
Just like camera inputs, monitor outputs on the Allegiant system are designed to be terminated. Each monitor output expects to be connected to a 75 ohm load. This is the regular load typically provided by a normal monitor. If a monitor output line is “looped” through several monitors or other equipment, the system installer should make sure that only the last unit on the line is terminated.
F.01U.127.393 2.0 2009.03 | Instruction Manual | Bosch Security Systems, Inc. |