19.3 AC Line Fuse Replacement

84 en

LTC 8600 LTC 8800 Series

19.3 AC Line Fuse Replacement

The AC line fuse on Allegiant power supply models is found on the rear of the equip- ment bay near the line cord connector. Power supply models for 220-240 VAC input version may contain a circuit breaker equipped power switch which can be reset directly from the front. If the line fuse needs to be replaced in a 120 VAC model power supply, remove the line cord from the system. Insert a flat blade screwdriver into the slot located at one end of the connector housing and rotate the screwdriver until the door to the housing opens. Remove fuse holder from housing as shown in drawing.

19.4 Power Supply Fuse Replacement19.5 Replacement of Memory Backup Batteries

Fusese Removal

Removal

Figure 21: Allegiant power supply AC line fuse

Remove fuse from holder and replace with fuse of same rating for continued protec- tion. Reinstall fuse holder into connector housing in the same orientation as indi- cated by the arrow on the door cover. Snap door closed. After replacing fuse, verify system start-up and operation.

19.4 Power Supply Fuse Replacement

The main power supply is located in the far right side of the equipment bay. Remove the front panel of the bay by loosening the four fasteners. Locate the fuse to be replaced by observing the green LED indicators. Note which LED indicators are not lit, then turn OFF the main power switch located on the power supply. Replace fuses associated with LEDs which were not lit. Switch on the main power switch and verify that all LEDs are now lit. Replace front panel.

19.5 Replacement of Memory Backup Batteries

General operational notes

Low battery conditions are indicated by LED on CPU and on-screen flashing “??

?? ??” of time/date fields.

Battery status can be check by keyboard operator using Keyboard User Func- tion 43.

Batteries are checked by CPU once per day at midnight, upon power up, and after system reset.

If batteries are replaced without power off/on (of at least 10 seconds) or reset of CPU, LED and on-screen indicators will not display normal until next mid- night is reached.

CAUTION Lithium batteries should be replaced by qualified service personnel only.

The memory backup batteries are located on the main CPU card located next to the power supply module in the main CPU bay. The batteries provide RAM memory backup for a period of at least one year. They are only active when main AC power to the system has been lost. The RAM memory is used to store system operational data