Bosch Appliances LTC 8600 Optional Accessories Installation, 9.1General Accessory Installation

Models: LTC 8600 LTC 8800

1 126
Download 126 pages 39.22 Kb
Page 40
Image 40
9 Optional Accessories Installation

34 en

LTC 8600 LTC 8800 Series

9 Optional Accessories Installation

9.1General Accessory Installation

There are many accessory products available for the Allegiant Series, including key- boards, alarm interface units, control code signal distribution units, etc. If applica- ble, these products can be installed at the same time as the main CPU bay installation, or postponed until later. In some cases, products are designed to be racked in close proximity to the main CPU bay, so appropriate rack space should be reserved.

Please refer to the instructions supplied with the specific accessory product for complete installation details.

9.2Logging Printer Option Installation

NOTE Although the exact installation procedure for each printer varies, the following steps are generally required. Be sure to save the printer reference manual for procedures not covered.

1.Switch the main power OFF to the printer.

2.Install the ribbon cartridge and paper if necessary.

3.Set any configuration switches for your particular printer to match the format provided by the Allegiant system. Note that the system communication protocol can be changed using the Keyboard User Functions (described later in this man- ual) or with the optional Allegiant LTC 8059 MCS package. The factory default values are as follows:

Baud rate --

115200

 

 

Stop bits --

1

 

 

Data bits --

8

 

 

Parity --

None

 

 

NOTE The required interconnect cable utilizes a custom pinout. Refer to the Appendix Section of this manual for wiring details.

4.Attach the 25-pin male D-type connector side of the RS-232 cable to the con- nector on the printer.

5.Attach the 9-pin male connector side of the cable to the Allegiant CPU bay con- nector marked “PRINTER”.

6.Apply power to the printer.

7.Verify logging printer action by ‘loading’ a previously stored sequence into a monitor, activating an alarm, or performing a system reset. Any of these actions should cause printouts to occur.

9.3Computer Interface Installation

NOTE Although the exact installation procedure for each computer varies, the following steps are generally required. Be sure to save the computer reference manual for pro- cedures not covered here. Switch the main power OFF to the computer.

Bosch Security Systems, Inc.

Instruction Manual

F.01U.127.393 2.0 2009.03

Page 40
Image 40
Bosch Appliances LTC 8600, LTC 8800 instruction manual Optional Accessories Installation, 9.1General Accessory Installation