Sequence & Display Mode
In the Sequence & Display mode alarm response mode, a monitor pair is used to display alarmed video.
Display | Sequence | Monitor Actions | Keyboard |
Monitor | Monitor |
| Operator |
|
|
| Action |
1st Alarm |
| D = Video associated with 1st | NONE |
Occurs |
| alarm is displayed. |
|
|
| S = Video associated with 1st |
|
|
| alarm is displayed. |
|
|
| D = Video associated with 1st | NONE |
|
| alarm is displayed. |
|
2nd Alarm |
| S = Video associated with 1st and |
|
Occurs |
| 2nd alarm is displayed. |
|
|
| D = Video associated with 1st | NONE |
|
| alarm is displayed. |
|
3rd Alarm |
| S = Video associated with 1st, 2nd |
|
Occurs |
| and 3rd alarm is displayed. |
|
|
| D = 1st alarm video is removed. | 1st Alarm |
|
| 2nd alarm video is now displayed. | Acknowledged |
|
| S = Video associated with 2nd and |
|
|
| 3rd alarms continue to sequence. |
|
|
| D = 2nd alarm video is removed. | 2nd Alarm |
|
| 3rd alarm video is now displayed. | Acknowledged |
|
| S = Only video associated with |
|
|
| 2nd alarm remains. |
|
|
| Since all alarms have been | 3rd Alarm |
|
| acknowledged, both monitors | Acknowledged |
|
| return to normal operator control. |
|
Bosch Security Systems, Inc. | Instruction Manual | F.01U.127.393 2.0 2009.03 |