8 Installation Procedure

28 en

LTC 8600 LTC 8800 Series

8 Installation Procedure

8.1Main CPU Bay Installation

Before discarding the shipping cartons, verify that the various pieces of equipment have no evidence of carrier damage.

CAUTION Do not apply power to the equipment until instructed to do so.

1.Remove the front panel of the main CPU bay and the front panels of any sup- plied expansion bay (LTC 8802 Series) by loosening the four (4) corner fasten- ers.

2.Install the power supply in far right position of the main CPU bay insuring proper alignment and seating of the module into the rear mating connector. Ver- ify that the power supply ON/OFF switch is in the OFF position. Repeat this procedure for any supplied LTC 8802 Series Monitor Expansion bay.

3.Install the four screws and star washers (supplied) on the rear panel of the bay(s) surrounding the power supply line cord to fasten the power supply securely in place.

CAUTION If the allegiant card cage is to be transported, the main power supply should be removed to prevent possible damage to the bay's internal parts.

4.If the bay(s) are to be installed into a standard 19-inch EIA rack, remove the four (4) rubber bumper foot pads found on the bottom of the bay before install- ing the unit in the rack. Four (4) holes are provided for mounting the bay(s) in the rack. If any LTC 8802 Series Monitor Expansion bay is supplied, it should be located as close as possible to the LTC 8801 Series Main CPU bay to facilitate cable interconnections.

5.Install the LTC 8600 Series, the LTC 8800 Series, and the LTC 8802 Series Moni- tor Expansion bays so that there is at least 9 cm (3.5 in.) of clearance above and below the bay. This clearance is necessary to allow for proper cooling of the system. Failure to provide proper clearance may cause the equipment to exceed its recommended operating temperature range.

NOTE An LTC 8802 Series Monitor Expansion bay should be located close enough to the TC8801 so that you can connect the units with the supplied 2 m (6 ft) data intercon- nect cable

8.2Video Input Modules

Termination switches on the Video Input Modules (VIM) must be set to the correct position prior to installation. If necessary, see Section 8.6 “Termination Practices,” on page 31 prior to actually installing the VIM on these systems.

The appropriate number of VIMs should be installed in the main bay starting with the left most slot. If the LTC 8802 Series Monitor Expansion Bay is being used, it should receive the same number of VIMs as the main bay. If less than full capacity is

Bosch Security Systems, Inc.

Instruction Manual

F.01U.127.393 2.0 2009.03

Page 34
Image 34
Bosch Appliances LTC 8600, LTC 8800 Installation Procedure, 8.1Main CPU Bay Installation, 8.2Video Input Modules