LTC 8600 LTC 8800 Series | en 81 |
|
|
diately be overridden by operators at the satellite location having any priority level. This situation is more likely to be encountered in
Since dual master configurations support
level master systems will result in the generation of priority based satellite com- mands.
The satellite number assigned to the system that is currently being programmed must be specified for the nnn value. This feature will enable use of the opera- tor's user priority to determine if access to a desired satellite camera is pro- vided or not. For instance, if no trunk lines are available and an operator requesting a satellite camera has higher priority than at least 1 of the existing operators, the requested camera will be switched. If the operator does not have sufficient priority, they will receive an error message (i.e., error 81) via the sat- ellite communication path, and their camera will switch to the
In addition, the same behavior for selecting trunk lines as described in the NO REM CAM CACHE option is applicable to this option. An operator's monitor will use the same trunk from the same bay as different cameras are selected, as long as no other operator is viewing the same satellite camera.
User Function 42 - Keyboard Log-in Auto-off Mode
Priority 1 users can use this function to select a keyboard
mode, move the joystick up or down to select the desired time period. Enter a valid password, and press [Enter]. If using the LTC 8555 keyboard, press [User] to exit the
mode.
User Function 43 - CPU Battery Status
Use this function to view the condition of the batteries used to backup CPU mem-
ory. Once the function is entered, the condition is displayed on the monitor text dis- play. If using the LTC 8555 keyboard, press [User] to exit the mode.
User Function 44 – Camera Vertical Phase Set
NOTE: This feature requires the following:
1.LTC 8621 or LTC 8821 video input modules having firmware 5.30 or later.
2.Dinion series of cameras using Bilinx communications.
3.AutoDome series of cameras using either Bilinx or Biphase data communica- tions.
4.LTC 8016/90 Bilinx Data Interface unit having firmware 1.01 or later.
5.All cameras configured to use Line Lock mode.
Priority 1 users can use this function to automatically adjust the phase interval delay of compatible cameras connected to the system. This will result in
After entering the function, the joystick down/up is used to select either an individ- ual camera to adjust or all cameras. Enter a valid user password number and press [Enter] to activate the adjustment process.
F.01U.127.393 2.0 2009.03 | Instruction Manual | Bosch Security Systems, Inc. |