17.5.2 Arm/Disarm All Alarms

66 en

LTC 8600 LTC 8800 Series

17.5.2 Arm/Disarm All Alarms

Press [Alarm Control], located on the main Allegiant menu screen to enter the menu screen containing these options. When using the IntuiKey keyboard:

To arm all alarms currently controlled on the monitor, press [Arm All Alarms].

To disarm all alarms, press [Disarm All Alarms].

When using the LTC 8555 Series keyboard:

To arm all alarms, press [User]. Then, press [Alarm] and then press [ON].

To disarm all alarms, press [OFF].

17.5.3Arm/Disarm Monitor

When using the IntuiKey keyboard:

Press [Alarm Control], located on the main Allegiant menu screen to enter the screen with these options.

To arm the monitor currently controlled, press [Arm Monitor].

To disarm the monitor, press [Disarm Monitor].

When using the LTC 8555 Series keyboard:

To arm the monitor, press [User]. Then, press [Monitor] and then press [ON] to arm all alarms.

To disarm all alarms, press [OFF].

NOTE Alarm video appears on a monitor only if the monitor is armed and the alarm is armed for that monitor. The monitor status display (if enabled) will show MA (moni- tor armed).

17.5.4 Alarms Acknowledgement

Bell [Ack] is provided so system operators can respond to alarms from the keyboard. Press Bell [Ack] when the keyboard is beeping (due to an alarm condition) to silence

the beeper. Depending on alarm configuration programming, subsequent pressing of Bell [Ack] either clears an alarm video from the monitors or has no effect.

17.6 Sequence Control

17.6.1 Load/Clear a Sequence

To load a previously programmed sequence to run on your monitor, press Load Sequence [Seq], enter the desired sequence number (1 to 60), then press [Enter].

Note that loading a sequence does not automatically start the sequence running. Since sequences may be programmed to use more than one monitor, all required monitors must be available. If a sequence is already on a monitor, the operator who loaded it originally (or an operator with a higher priority) is permitted to load a new sequence on the monitor(s). Others will receive an error message.

To clear a monitor sequence, press Load sequence [Seq], then press [Enter]. Only the operator who originally loaded it (or an operator with a higher priority) is permitted to clear a monitor sequence. Others will receive an error message. If enabled, the status display area of the monitor indicates the sequence number in the appropriate location. If no sequence is currently loaded, 00 is displayed.