116 en AppendixVideoJet X40 SN
8.9 | Communication with Terminal Program |
Data Terminal
If a VideoJet X40 SN cannot be found in the network or the connection to the network is interrupted, you can connect a data terminal to the VideoJet X40 SN for initial setup and setting of important parameters. The data terminal consists of a computer with a terminal program.
You require a serial transmission cable with a
HyperTerminal, a communications accessory included with Microsoft Windows, can be used as the terminal program.
NOTICE!
i Information on installing and using HyperTerminal can be found in the manuals or in the online help for Microsoft Windows.
1.Disconnect the VideoJet X40 SN from the Ethernet network before working with the terminal program.
2.Connect the serial interface of the VideoJet X40 SN using any available serial interface on the computer.
Configuring the Terminal
Before the terminal program can communicate with the VideoJet X40 SN, the transmission parameters must be matched. Make the following settings for the terminal program:
–19,200 bps
–8 data bits
–No parity check
–1 stop bit
–No protocol
Command Inputs
After the connection has been established, you must log on to the VideoJet X40 SN to access the main menu. Other submenus and functions can be accessed using the
1.If necessary, turn off the local echo so that entered values are not repeated on the display.
2.Enter one command at a time.
3.When you have entered a value, such as the IP address, check the characters you have entered before pressing Enter to transfer the values to the VideoJet X40 SN.
DOC V4.0 2009.06 | Installation and Operating Manual | Bosch Security Systems |