74 en Configuration Using a Web Browser

VideoJet X40 SN

 

 

Trigger active

Select the VCA configuration here that is to be enabled via an active trigger. A green check mark to the right of the list field indicates that the trigger is active.

Trigger inactive

Select the VCA configuration here that is to be activated if the trigger is not active. A green check mark to the right of the list field indicates that the trigger is inactive.

Delay (s)

Select the delay period here for the reaction of the video content analysis to trigger signals. A delay period may be useful in avoiding false alarms or frequent triggering, for example. During the delay period, the Silent MOTION+ configuration is always enabled.

5.32

Advanced Mode: Audio Alarm

The VideoJet X40 SN can create alarms on the basis of audio signals. You can configure signal strengths and frequency ranges in such a way that false alarms, for example due to machine noise or background noise, are avoided.

NOTICE!

i First set up normal audio transmission before you configure the audio alarm here (see Section 5.20 Advanced Mode: Audio, page 52).

Audio alarm

Select On if you want the unit to generate audio alarms from the input in question.

DOC V4.0 2009.06

Installation and Operating Manual

Bosch Security Systems

Page 74
Image 74
Bosch Appliances X40 SN manual Advanced Mode Audio Alarm, Trigger active, Trigger inactive, Delay s, Audio alarm