WARNING Exhaust heat/gases could ignite combustibles or

 

 

WARNING Hot pressurized coolant could cause serious injury.

 

 

 

structures resulting in death or serious injury.

 

 

 

 

 

 

Contact with muffler area could cause burns

 

 

 

 

 

 

resulting in serious injury.

 

 

 

• DO NOT open radiator cap when hot.

 

 

 

 

 

 

• DO NOT touch hot parts and AVOID hot exhaust gases.

 

 

Before servicing, allow coolant to cool.

Allow equipment to cool before touching.

 

 

 

 

 

 

Exhaust outlet side of weatherproof enclosure must have at least

 

 

CAUTION Installing the 15A fuse could cause the engine

 

5 ft. (1.5m) minimum clearance from any structure, shrubs, trees

 

 

to start at any time without warning resulting in minor or

 

or any kind of vegetation.

 

 

 

 

moderate injury.

Standby generator weatherproof enclosure must be at least

 

Observe that the 15 Amp fuse has been removed from the control

 

5 ft. (1.5m) from windows, doors, any wall opening, shrubs or

 

 

vegetation over 12 inches (30.5 cm) in height.

 

 

 

panel for shipping.

Standby generator weatherproof enclosure must have a minimum

 

DO NOT install this fuse until all plumbing and wiring has been

 

of 5 ft. (1.5 m) overhead clearance from any structure, overhang,

 

 

completed and inspected.

 

or trees.

 

 

 

 

 

 

• DO NOT place weatherproof enclosure under a deck or other type

 

 

CAUTION Excessively high operating speeds could result in

 

minor injury and/or equipment damage.

 

of structure that may confine airflow.

 

 

 

 

 

 

 

Excessively low speeds impose a heavy load on generator.

Use only flexible fuel line provided. Connect provided fuel line to

 

 

DO NOT tamper with governed speed. Generator supplies correct

 

generator. DO NOT use with or substitute any other flexible

 

 

 

 

rated frequency and voltage when running at governed speed.

 

fuel line.

 

 

 

 

 

 

 

 

 

 

• DO NOT modify generator in any way.

Smoke detector(s) MUST be installed and maintained indoors

 

 

 

 

 

according to the manufacturer’s instructions/recommendations.

 

NOTICE Exceeding generators wattage/amperage capacity could

 

Carbon monoxide alarms cannot detect smoke.

 

 

 

 

 

damage generator and/or electrical devices connected to it.

Keep at least minimum distances shown in General Location

 

 

Start generator and let engine stabilize before connecting

 

Guidelines to insure for proper generator cooling and

 

 

electrical loads.

 

maintenance clearances.

 

 

 

NOTICE Improper treatment of generator could damage it and

• Replacement parts must be the same and installed in the same

 

 

shorten its life.

 

position as the original parts.

 

 

 

 

 

 

 

Use generator only for intended uses.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

If you have questions about intended use, contact your

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

authorized dealer.

 

WARNING Moving parts could crush and cut.

 

 

Operate generator only on level surfaces.

 

 

 

 

Starter and other rotating parts

 

Adequate, unobstructed flow of cooling and ventilating air is

 

 

 

 

could entangle hands, hair, clothing,

 

 

 

 

 

 

 

critical to correct generator operation.

 

 

 

 

or accessories resulting in serious injury.

 

 

 

 

 

 

 

The access panels/door must be installed whenever the unit

NEVER operate generator without protective housings, covers, or

 

 

 

is running.

 

guards in place.

NOT

 

 

 

 

 

 

DO NOT expose generator to excessive moisture, dust, dirt, or

 

 

 

 

 

DO NOT wear loose clothing, jewelry or anything that could be

 

 

 

corrosive vapors.

 

caught in the starter or other rotating parts.

 

 

 

 

 

 

 

 

Tie up long hair and remove jewelry.

for

 

 

Remain alert at all times while working on this equipment.

 

 

 

 

Never work on the equipment when you are physically or

Before servicing, remove 15 Amp fuse from control panel and

 

 

 

 

mentally fatigued.

 

disconnect Negative (NEG or -) battery cable.

REPRODUCTION

 

 

 

DO NOT start engine with air cleaner or air cleaner cover removed.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DO NOT insert any objects through cooling slots.

 

 

 

 

 

 

 

 

DO NOT use the generator or any of its parts as a step. Stepping

 

 

 

 

 

 

 

 

 

on the unit could cause stress and break parts. This may result in

 

 

 

 

 

 

 

 

 

dangerous operating conditions from leaking exhaust gases, fuel

 

 

 

 

 

 

 

 

 

leakage, oil leakage, etc.

 

 

 

 

 

 

 

 

If connected devices overheat, turn them off and disconnect them

 

 

 

 

 

 

 

 

 

from generator.

 

 

 

 

 

 

 

 

Shut off generator if:

 

 

 

 

 

 

 

 

 

-electrical output is lost;

 

 

 

 

 

 

 

 

 

-equipment sparks, smokes, or emits flames;

-unit vibrates excessively.

-unit makes unusual noises.

6