Rated Maximum Load Current (at 40°C/104°F, LP*):
at 240 Volts | 146 Amps |
Rated AC Voltage | 120/240 Volts |
Phase | Single phase |
Rated Frequency | 60 Hertz |
Normal Operating Range | |
Output Sound Level | 68 dB(A) at 23 ft. (7 m) |
| at normal load |
Shipping Weight | 2120 lb (962 kg) |
* Natural gas rating will depend on specific fuel but typical derates are between | |
10 to 20% off the LP gas rating. | REPRODUCTION |
|
Power Ratings: The gross power rating for individual gasoline engine models is labeled in accordance with SAE (Society of Automotive Engineers) code J1940 Small Engine Power & Torque Rating Procedure, and is rated in accordance with SAE J1995. Torque values are derived at 2600 RPM for those engines with “rpm” called out on the label and 3060 RPM for all others; horsepower values are derived at 3600 RPM. The gross power curves can be viewed at www.BRIGGSandSTRATTON.COM. Net power values are taken with exhaust and air cleaner installed whereas gross power values are collected without these attachments. Actual gross engine power will be higher than net engine power and is affected by, among other things, ambient operating conditions and
are placed, the gasoline engine may not develop the rated gross power when used in a given piece of power equipment. This difference is due to a variety of factors including, but notNOTlimited to, the variety of engine components (air cleaner, exhaust, charging, cooling, carburetor, fuel pump, etc.), application limitations, ambient operating conditions (temperature, humidity, altitude), and
for
This generator is rated in accordance with UL (Underwriters Laboratories) 2200 (stationary engine generator assemblies) and CSA (Canadian Standards Association) standard C22.2 No.
30