Chapter 6 Maintaining the Router

Removing and Replacing the Blower Module

Figure 6-6 Installing the Blower Module

1

2

3

129402

1

2

Carrying handle

3 Guide pins

Captive screws (2 on each side)

Troubleshooting the Blower Installation

Use the following procedure to troubleshoot the blower module if it is not operating properly after installation.

Step 1 Be sure the router is powered on and that all power cords are connected properly.

Step 2 Loosen the four captive screws and reseat the blower module to the chassis. Retighten the captive screws to ensure the blower module is properly seated to the backplane connector.

 

Cisco 12006 and Cisco 12406 Router Installation and Configuration Guide

6-12

OL-11497-03

Page 252
Image 252
Cisco Systems Cisco 12406, Cisco 12006 manual Troubleshooting the Blower Installation