6-35
Cisco 12006 and Cisco 12406 Router Installation and Configuration Guide
OL-11497-03
Chapter 6 Maintaining the Router
Removing and Replacing a DC PEM
Step 5 Power on the circuit breaker.
Step 6 Set the power switch to the On position.
The AC Input and DC Output power indicators on the front of the power supply
should light. If the indicators do not light, or the Miswire indicator is on, see the
“Troubleshooting the DC Power Supply Installation” section on page 6-35.
Troubleshooting the DC Power Supply Installation
Use the following procedure to troubleshoot the DC power supply if it is not
operating properly after installation.
Step 1 Make sure the power supply is seated properly:
Eject and reseat the power supply.
The captive screw on the ejector lever are tightened securely.
The power switch is set to the On (1) position.
Step 2 Make sure the router is powered on and that all power cables are connected
properly:
Power leads are securely connected to the power connector block on the PDU.
Power cables are securely connected at the DC source connection.
The source DC circuit breaker is turned on.