3-19
Cisco 12006 and Cisco 12406 Router Installation and Configuration Guide
OL-11497-03
Chapter 3 Installing the Router
Connecting to the Console and Auxiliary Ports
Caution The ports labeled Ethernet, 10BASE-T, Token Ring, Console, and AUX are safety
extra-low voltage (SELV) circuits. SELV circuits should only be connected to
other SELV circuits.
Note RP cables are not available from Cisco, but are available from any commercial
cable vendor.
Note To comply with Telcordia GR-1089 NEBS standard for electromagnetic
compatibility and safety, connect all console, auxiliary, Ethernet, and
BITS (PRP2) interfaces only to intrabuilding or nonexposed wiring or cabling.
The intrabuilding cable must be shielded and the shield must be grounded at both
ends.
PRP Console Port Signals
The console port on the PRP is a DCE RJ-45 receptacle. Table 3-3 lists the
signal-to-pin correspondence for the PRP console port.
Tab l e 3-3 PRP Console Port Signals
Console Port Pin Signal Input/Output Description
11
1. These pins are not connected.
— —
2DTR Output Data Terminal Ready
3TxD Output Transmit Data
4GND Signal Ground
5GND Signal Ground
6RxD Input Receive Data
7DSR Input Data Set Ready
81— —