Cisco Systems Cisco 12006, Cisco 12406 Maintaining the Router Removing and Replacing an AC PEM

Models: Cisco 12006 Cisco 12406

1 340
Download 340 pages 3.61 Kb
Page 259
Image 259

Chapter 6 Maintaining the Router

Removing and Replacing an AC PEM

Use the following procedure to remove and replace an AC power supply.

Caution You cannot mix power supply types within the chassis. If you are replacing a 1400 W power supply from an older system with a new 1900 W power supply, you must replace both power supplies, the AC PDU, and the blower module if you are required to meet NEBS extended temperature range requirements (see the “Power Supply and PDU Compatibility” section on page 6-14 for additional information). You must shut down the router to perform the upgrade. Notify the system administrator and other appropriate personnel that all routing traffic stops while upgrades take place.

Step 1 Set the power switch to the Off (0) position.

Step 2 Unplug the power supply cord from its AC outlet.

Step 3 Power off the circuit breaker assigned to that AC outlet.

 

 