Chapter 5 Field Diagnostics for the Cisco 12000 Series Router
Using the diag Command

5-14

Cisco 12006 and Cisco 12406 Router Installation and Configuration Guide
OL-11497-03
Output Examples

The following example shows the output when field diagnostics are performed on

the line card in slot 7. After the line card passes all field diagnostic tests, the

Cisco IOS software automatically reloads on the card. Before starting the

diagnostic tests, you must confirm the request to perform these tests on the line

card because all activity on the line card is halted. The total/indiv. timeout set to

2000/600 sec. message indicates that 2000 seconds are allowed to perform all

field diagnostics tests, and that no single test should exceed 600 seconds to

complete.

Router# diag 7 source tftp
tftp://192.164.5.4/images/c12k-fdiagsbflc-mz.120-25.S
Running DIAG config check
Fabric Download for Field Diags chosen: If timeout occurs, try 'mbus'
option.
Running Diags will halt ALL activity on the requested slot. [confirm]
award-rp-slot0#
Launching a Field Diagnostic for slot 7
Downloading diagnostic tests to slot 7 via fabric (timeout set to 300
sec.)
5d20h: %GRP-4-RSTSLOT: Resetting the card in the slot: 7,Event:
EV_ADMIN_FDIAG
Loading images/award/c12k-fdiagsbflc-mz from 192.164.1.1 (via
Ethernet0): !!!!!
5d20h: Downloading diags from tftp file
tftp://192.164.1.1/images/award/c12k-fdiagsbflc-mz
!!!!![OK - 13976524 bytes]
FD 7> *****************************************************
FD 7> GSR Field Diagnostics V6.05
FD 7> Compiled by award on Tue Jul 30 13:00:41 PDT 2002
FD 7> view: award-conn_isp.FieldDiagRelease
FD 7> *****************************************************
Executing all diagnostic tests in slot 7
(total/indiv. timeout set to 2000/600 sec.)
FD 7> BFR_CARD_TYPE_OC12_4P_POS testing...
FD 7> Available test types 2
FD 7> 1
FD 7> Completed f_diags_board_discovery() (0x1)
FD 7> Test list selection received: Test ID 1, Device 0
FD 7> running in slot 7 (30 tests from test list ID 1)
FD 7> Skipping MBUS_FDIAG command from slot 2
FD 7> Just into idle state
Field Diagnostic ****PASSED**** for slot 7
Shutting down diags in slot 7
Board will reload