5-5
Cisco SFS 7000P Hardware Installation Guide
OL-9167-01 Rev. A0
Chapter5 Hardware Diagnostic Tests
Running Fan Tests
fan(1) passed none
Running Fan Tests
The following sections describes the fan module tests:

Running a Self-Test on a Fan

To perform a diagnostic self-test on a fan, follow these steps:
Step1 Identify the number of the fan you want to diagnose, if you do not already know
the number.
Enter the show fan command.
SFS-7000P# show diagnostic fan
======================================================================
Diagnostic Tests For Fan
======================================================================
module-type : fan
module-number : 2
test : self-test
iterations : 1
action : start
result : success
percentage-completed : 100
result-string : Fan Self Test Completed, Final report :
Passed=1, Failed=0, Total=1
Step2 Enter the diag fan id command.
SFS-7000P# config
SFS-7000P(config)# diag fan 1
SFS-7000P(config-diag-fan-1)# test self-test
SFS-7000P(config-diag-fan-1)# start
SFS-7000P(config-diag-fan-1)# exit
SFS-7000P(config)# exit
SFS-7000P# show diag fan
======================================================================
Diagnostic Tests For Fan