Chapter 5 Hardware Diagnostic Tests

Running Fan Tests

fan(1)

passed

none

 

 

 

Running Fan Tests

The following sections describes the fan module tests:

Running a Self-Test on a Fan

To perform a diagnostic self-test on a fan, follow these steps:

Step 1 Identify the number of the fan you want to diagnose, if you do not already know the number.

Enter the show fan command.

SFS-7000P#show diagnostic fan

======================================================================

Diagnostic Tests For Fan

======================================================================

module-type : fan module-number : 2

test : self-test iterations : 1

action : start

result : success

percentage-completed : 100

result-string : Fan Self Test Completed, Final report : Passed=1, Failed=0, Total=1

Step 2 Enter the diag fan id command.

SFS-7000P# config SFS-7000P(config)# diag fan 1

SFS-7000P(config-diag-fan-1)# test self-test SFS-7000P(config-diag-fan-1)# start SFS-7000P(config-diag-fan-1)# exit SFS-7000P(config)# exit

SFS-7000P# show diag fan

======================================================================

Diagnostic Tests For Fan

 

 

Cisco SFS 7000P Hardware Installation Guide

 

 

 

 

 

 

OL-9167-01 Rev. A0

 

 

5-5

 

 

 

Page 67
Image 67
Cisco Systems Cisco SFS 7000P manual Running Fan Tests, Running a Self-Test on a Fan, SFS-7000P#show diagnostic fan