Chapter5 Hardware Diagnostic Tests
Running Power Supply Tests
5-8Cisco SFS 7000P Hardware Installation Guide
OL-9167-01 Rev. A0
Enter the show power-supply command. SFS-7000P# show power-supply
=====================================================================
Power-supply Information
=====================================================================
ps type admin-status oper-status utilization voltage
---------------------------------------------------------------------
1 AC up up n/a 48
2 AC up up 15 47
Step2 Specify the type of test (self-test is chosen by default) by entering the diag
power-supply id command.SFS-7000P> enable
SFS-7000P# config
SFS-7000P(config)# diag power-supply 2
SFS-7000P(config-diag-power-supply-2)# test self-test
Step3 Start the test.
SFS-7000P(config-diag-power-supply-2)# start
Step4 Display the progress of the test by entering the show diag fan command.
SFS-7000P(config-diag-power-supply-2)# exit
SFS-7000P(config)# exit
SFS-7000P# show diagnostic power-supply
======================================================================
Diagnostic Tests For Power Supply
======================================================================
module-type : power-supply
module-number : 2
test : self-test
iterations : 1
action : start
result : success
percentage-completed : 100
result-string : Power Supply Self Test Completed, Final
report : Passed=1, Failed=0, Total=1
Step5 Display any errors that appear in the result string by entering the show diag
fru-error command.SFS-7000P# show diag fru-error
================================================================
Fru-Error
================================================================