Chapter 5 Hardware Diagnostic Tests

Displaying Hardware Errors

fru-slot fru-error

----------------------------------------------------------------

card(9)

none

card(10)

none

card(11)

none

card(12)

none

card(13)

none

card(14)

none

card(15)

none

card(17)

none

fan(1)

none

fan(2)

none

fan(3)

none

fan(4)

none

power-supply(1) none power-supply(2) none SFS-7000P#

Step 6 Reboot the chassis when the self-test is complete.

SFS-7000P# reload

System configuration is modified. Save? [yes(default) no filename] y

Proceed with reload? [yes(default) no] y

Displaying Hardware Errors

To display POST results, non-fatal errors that can are recovered, informational logging (such as firmware updates), and hardware errors:

To display hardware errors, follow these steps:

Step 1 Locate the /topspin/log/hwif_log file by entering the more syslog:hwif_log command.

 

SFS-7000P>

enable

 

SFS-7000P#

more syslog:hwif_log

 

Thu Mar

4

10:57:49 2004: POST: SEEPROM: PASSED

 

Thu Mar

4

10:57:49 2004: POST: FPGA: PASSED

 

Thu Mar

4

10:57:49 2004: POST: SUMMIT: PASSED

 

Thu Mar

4

10:57:50 2004: POST: RTC: PASSED

 

Thu Mar

4

10:57:54 2004: POST: FAN: PASSED

 

Thu Mar

4

10:57:54 2004: card_startup.x : card is starting up

 

 

 

Cisco SFS 7000P Hardware Installation Guide

 

 

 

 

 

 

 

OL-9167-01 Rev. A0

 

 

 

5-9

 

 

 

 

Page 71
Image 71
Cisco Systems Cisco SFS 7000P manual Displaying Hardware Errors, Enable, More sysloghwiflog