Chapter5 Hardware Diagnostic Tests
Running Chassis Tests
5-4
Cisco SFS 7000P Hardware Installation Guide
OL-9167-01 Rev. A0
SFS-7000P> enable
SFS-7000P# config
SFS-7000P(config)# diag chassis test standard
SFS-7000P(config-diag-chassis)# start
SFS-7000P(config-diag-chassis)#

Step2 Display the status of the test by entering the show diag chassis command.

SFS-7000P(config-diag-chassis)# exit
SFS-7000P(config)# exit
SFS-7000P# show diag chassis
======================================================================
Diagnostic Tests For Chassis
======================================================================
module-type : chassis
module-number : 1
test : standard
iterations : 1
option : none
action : start
result : success
percentage-completed : 100
result-string : Standard System Test Completed, Final report :
Passed=1, Failed=0, Total=1
SFS-7000P#

Step3 Display any errors on individual components by entering the show diag post

command.
SFS-7000P-1# show diag post
======================================================================
Post Status
======================================================================
fru-slot post-status post-error
----------------------------------------------------------------------
card(1) failed _FRU_LIM_CARDTYPE_ERR
card(3) failed _FRU_SEEPROM_PROGRAM_ERR
card(5) passed none
card(6) passed none
card(7) passed none
card(8) passed none
card(9) passed none
card(11) failed _FRU_POWER_CONTROLLER_CONFIG_ERR
card(12) passed none
card(13) passed none
card(15) passed none
card(16) passed none
card(17) passed none