Chapter 12 Managing Alarms

Creating, Editing, and Duplicating Alarm Thresholds

Table 12-16

ACS System Diagnostics

 

 

 

Option

 

Description

 

 

Severity at and above

Use the drop-down list box to choose the severity level on which you want to configure your

 

 

threshold. This setting captures the indicated severity level and those that are higher within the

 

 

threshold. Valid options are:

 

 

Fatal

 

 

Error

 

 

Warning

 

 

Info

 

 

Debug

 

 

 

Message Text

 

Enter the message text on which you want to configure your threshold. Maximum character limit is

 

 

1024.

 

 

 

 

Filter

 

 

 

ACS Instance

Click Select to choose a valid ACS instance on which to configure your threshold.

Related Topics

Creating, Editing, and Duplicating Alarm Thresholds, page 12-11

Configuring General Threshold Information, page 12-13

Configuring Threshold Notifications, page 12-32

ACS Process Status

When ACS evaluates this threshold, it examines the accounting records that it received during the interval between the previous and current alarm evaluation cycle.

If one or more accounting records match, it calculates the time that has lapsed since the previous alarm evaluation cycle. When it reaches two, three, or five minutes depending on the number of active thresholds, ACS determines whether any ACS process has failed during that time.

If ACS detects one or more failures, an alarm is triggered. You can limit the check to particular processes or a particular ACS instance or both.

Choose this category to define threshold criteria based on ACS process status. Modify the fields in the Criteria tab as described in Table 12-17.

Table 12-17 ACS Process Status

Option

Description

Monitor Processes

 

ACS Database

Check the check box to add the ACS database to your threshold configuration.

 

 

 

 

 

 

ACS Management

Check the check box to add the ACS management to your threshold

 

 

configuration.

 

 

 

 

 

ACS Runtime

Check the check box to add the ACS runtime to your threshold configuration.

 

 

 

 

 

Monitoring and Reporting Database

Check the check box to have this process monitored. If this process goes down,

 

 

an alarm is generated.

 

 

 

 

 

 

 

 

User Guide for Cisco Secure Access Control System 5.3

 

 

 

 

 

 

 

 

 

 

 

 

 

OL-24201-01

 

 

12-23

 

 

 

 

 

Page 351
Image 351
Cisco Systems OL-24201-01 manual ACS Process Status, 12-23