Appendices ~ Appendix E: Serial Commands

109

LOCKPRST - Apply the lock to a preset or macro

Selects/reports whether the lock is applied to a preset/macro. If a preset/macro has the lock applied, it can be changed only if unlocked with the password.

Command form: DEVICE LOCKPRST <Channel><Group>[Value]

Argument details

Name

Description

Device

0–7 or * to select all units

LOCKPRST

Command form

Channel

1–32 (Preset) or 1–255 (Macro)

Group

S = Preset, C = Macro

Value

0 = Off, 1 = On, 2 = Toggle, Null = Query (value is

 

returned only if unit is unlocked)

Example: #42 LOCKPRST 5 S 1 On PSR1212 unit 2 (#42), preset 5 (5 S) will be protected (1) whenever the lock option is enabled.

LOCKPWD - Set preset/macro password

Selects/reports the password for the preset/macro lock. This can be changed only if the unit is unlocked.

Command form: DEVICE LOCKPWD [Value]

Argument details

Name

Description

Device

0–7 or * to select all units

LOCKPWD

Command form

Value

1–12 characters

 

Null = Query (value is returned only if unit is unlocked)

Example: #43 LOCKPWD mypassword On PSR1212 unit 3 (#43), the macro/preset password (LOCKPWD) is set to mypassword.

LVL - Level

This command reports the level. This command is read only.

Command form: DEVICE LVL <Channel> <Group> [Position] [Value]

Argument details

Name

Description

Units

Device

0–7 or * to select all units

 

LVL

Command form

 

Channel

See Groups and Channels, page 93

 

Group

See Groups and Channels, page 93

 

Position

See Meter Type Definitions, page 94

 

Value

-99.99 to 99.99

dB

 

Sent with Null in text, value returned

 

Example: #41 LVL 8 L I 3 The level (LVL) received from PSR1212 unit 1 (#41) for line level (L) Input 8 at the Input stage (I) is 3dB.

Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760

Page 115
Image 115
ClearOne comm PSR1212 109, Lockprst Apply the lock to a preset or macro, Lockpwd Set preset/macro password, LVL Level