Appendices ~ Appendix E: Serial Commands

121

SFTYMUTE - Safety mute

Selects/reports the state of the safety mute. When on, the safety mute holds all outputs on the selected unit in a muted state. It is used primarily for troubleshooting G-Ware.

Command form: DEVICE SFTYMUTE [Value]

Argument details

Name

Description

Device

0–7 or * to select all units

SFTYMUTE

Command

Value

0 = Off, 1 = On, 2 = Toggle, Null = Current state

Example: #42 SFTYMUTE 1 On PSR1212 unit 2 (#42), safety mute

(SFTYMUTE) is enabled (1).

SIGGEN - Signal Generator

This command selects/reports of the signal generator activation.

Command form: DEVICE SIGGEN <Channel> <Group> [Type] [Amplitude] [Frequency]

Argument details

Name

Description

Device

0–7 or * to select all units

SIGGEN

Command

Channel

See Groups and Channels, page 93

Group

I, M, L

Type

0 = Off, 1 = Pink, 2 = White, 3 = Tone, Null = Current state

Amplitude

-60 to +20 amplitude in dB; NULL for type 0

Frequency

20 to 20,000 frequency in Hz (needed only when using tone

 

generation)

Example: #46 SIGGEN 1 M 2 0 On PSR1212 unit 6 (#46), the signal gen- erator (SIGGEN) is set to input at mic (M) channel 1 with white noise (2) at 0dB.

Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760

Page 127
Image 127
ClearOne comm PSR1212 operation manual Sftymute Safety mute, Siggen Signal Generator