Appendices ~ Appendix E: Serial Commands | 121 |
SFTYMUTE - Safety mute
Selects/reports the state of the safety mute. When on, the safety mute holds all outputs on the selected unit in a muted state. It is used primarily for troubleshooting
Command form: DEVICE SFTYMUTE [Value]
Argument details
Name | Description |
Device | |
SFTYMUTE | Command |
Value | 0 = Off, 1 = On, 2 = Toggle, Null = Current state |
Example: #42 SFTYMUTE 1 On PSR1212 unit 2 (#42), safety mute
(SFTYMUTE) is enabled (1).
SIGGEN - Signal Generator
This command selects/reports of the signal generator activation.
Command form: DEVICE SIGGEN <Channel> <Group> [Type] [Amplitude] [Frequency]
Argument details
Name | Description |
Device | |
SIGGEN | Command |
Channel | See Groups and Channels, page 93 |
Group | I, M, L |
Type | 0 = Off, 1 = Pink, 2 = White, 3 = Tone, Null = Current state |
Amplitude | |
Frequency | 20 to 20,000 frequency in Hz (needed only when using tone |
| generation) |
Example: #46 SIGGEN 1 M 2 0 On PSR1212 unit 6 (#46), the signal gen- erator (SIGGEN) is set to input at mic (M) channel 1 with white noise (2) at 0dB.