The calibration utility calibrates one battery pack at a time and can run in the background as you use the computer or overnight.

CAUTION: To prevent loss of work, ensure that the computer remains connected to AC power throughout a calibration.

Running a Calibration

1.If you are checking the calibration of a battery pack—Insert the battery pack into the computer battery bay, a DualBay, or a MultiBay.

If you are calibrating a battery pack—Insert the battery

pack into the computer battery bay, a DualBay, or a MultiBay. Then connect the computer to external power with the AC adapter or dock the computer in a docking base that is connected to external power.

2.Access the Battery Calibration tab.

In Windows 95 select StartSettingsControl PanelPowerBattery Calibration tab.

In Windows 98 select StartSettingsControl PanelPower ManagementBattery Calibration tab.

In Windows NT 4.0 select StartSettingsControl PanelCompaq PowerBattery Calibration tab.

3.View the calibration reports in the Status column. The battery numbers in the Battery column correspond to the following locations:

Battery Number

1

2

3

Battery Pack Location

Computer battery bay

Computer DualBay

Computer MultiBay

4.Select any location number with “Needs calibration” beside it in the Status column.

5.Select the Start Calibration button.