Table
Code | Text | Causes | Corrective Actions |
|
|
|
|
E1810 | HDD ## Fault | The SAS subsystem has | See "Troubleshooting a Hard |
|
| determined that hard drive ## | Drive" on page 104. |
|
| has experienced a fault. |
|
E1811 HDD ## Rbld Abrt The specified hard drive has experienced a rebuild abort.
See "Troubleshooting a Hard Drive" on page 104. If the problem persists, see your RAID documentation.
E1812 | HDD ## Removed | The specified hard drive has been Information only. |
|
| removed from the system. |
E1913 | CPU & Firmware | The BMC firmware does not |
| Mismatch | support the CPU. |
Update to the latest BMC firmware. See the BMC User’s Guide for more information on setup and use of BMC.
E1A14 | SAS Cable A | SAS cable A is missing or bad. |
Reseat the cable. If the problem persists, replace the cable. See "SAS Controller Daughter Card" on page 56.
E1A15 | SAS Cable B | SAS cable B is missing or bad. |
Reseat the cable. If the problem persists, replace the cable. See "SAS Controller Daughter Card" on page 56.
E1A17 | Pwr Cable FB | Flex bay power cable is missing or |
|
| bad. |
Reseat the cable. If the problem persists, replace the cable. See "SAS Controller Daughter Card" on page 56.
E1A18 | PDB Ctrl Cable | Flex bay control signals cable is |
|
| missing or bad. |
Reseat the cable. If the problem persists, replace the cable. See "SAS Controller Daughter Card" on page 56.
E2010 | No Memory | No memory is installed in the | Install memory. See "Installing |
|
| system. | Memory Modules" on page 65. |
|
|
|
|
E2011 | Mem Config Err | Memory detected, but is not | See "Troubleshooting System |
|
| configurable. Error detected | Memory" on page 102. |
|
| during memory configuration. |
|
|
|
|
|
E2012 | Unusable Memory | Memory is configured, but not | See "Troubleshooting System |
|
| usable. Memory subsystem | Memory" on page 102. |
|
| failure. |
|
|
|
|
|
E2013 | Shadow BIOS Fail | The system BIOS failed to copy | See "Troubleshooting System |
|
| its flash image into memory. | Memory" on page 102. |
About Your System