Dell 1950 E2014 Cmos Fail, E2015 DMA Controller, E2016 Int Controller, E2017 Timer Fail

Models: 1950

1 160
Download 160 pages 35.77 Kb
Page 22
Image 22

Table 1-7. LCD Status Messages (continued)

Code

Text

Causes

Corrective Actions

 

 

 

 

E2014

CMOS Fail

CMOS failure. CMOS RAM not

See "Getting Help" on page 125.

 

 

functioning properly.

 

 

 

 

 

E2015

DMA Controller

DMA controller failure.

See "Getting Help" on page 125.

 

 

 

 

E2016

Int Controller

Interrupt controller failure.

See "Getting Help" on page 125.

 

 

 

 

E2017

Timer Fail

Timer refresh failure.

See "Getting Help" on page 125.

 

 

 

 

E2018

Prog Timer

Programmable interval timer

See "Getting Help" on page 125.

 

 

error.

 

 

 

 

 

E2019

Parity Error

Parity error.

See "Getting Help" on page 125.

 

 

 

 

E201A

SIO Err

SIO failure.

See "Getting Help" on page 125.

 

 

 

 

E201B

Kybd Controller

Keyboard controller failure.

See "Getting Help" on page 125.

 

 

 

 

E201C

SMI Init

System management interrupt

See "Getting Help" on page 125.

 

 

(SMI) initialization failure.

 

 

 

 

 

E201D

Shutdown Test

BIOS shutdown test failure.

See "Getting Help" on page 125.

 

 

 

 

E201E

POST Mem Test

BIOS POST memory test failure.

See "Troubleshooting System

 

 

 

Memory" on page 102. If the

 

 

 

problem persists, see "Getting

 

 

 

Help" on page 125.

E201F

DRAC Config

Dell remote access controller

 

 

(DRAC) configuration failure.

Check for specific error messages.

Ensure that DRAC cables and connectors are properly seated. If the problem persists, see your DRAC documentation.

E2020

CPU Config

CPU configuration failure.

Check for specific error messages.

 

 

 

 

E2021

Memory

Incorrect memory configuration.

Check for specific error messages.

 

Population

Memory population order

See "Troubleshooting System

 

 

incorrect.

Memory" on page 102.

 

 

 

 

E2022

POST Fail

General failure after video.

Check for specific error messages.

 

 

 

 

E2110

MBE Crd # DIMM ##

One of the DIMMs in the set

See "Troubleshooting System

 

& ##

implicated by "## & ##" has

Memory" on page 102.

 

 

had a memory multi-bit error

 

(MBE). If no memory card is present, the "Crd #" string is left out of the message.

22

About Your System

Page 22
Image 22