Dell 1950 No boot sector on hard, Drive, No timer tick interrupt, Northbound merge error, Error

Models: 1950

1 160
Download 160 pages 35.77 Kb
Page 28
Image 28

Table 1-8. System Messages (continued)

Message

Causes

Corrective Actions

 

 

 

No boot sector on hard

Incorrect configuration settings in

Check the hard-drive configuration

drive

System Setup program, or no

settings in the System Setup program.

 

operating system on hard drive.

See "Using the System Setup Program"

 

 

on page 33. If necessary, install the

 

 

operating system on your hard drive. See

 

 

your operating system documentation.

 

 

 

No timer tick interrupt

Faulty system board.

See “"Getting Help" on page 125."

 

 

 

Northbound merge error -

The specified DIMM was unable to

See "Troubleshooting System Memory"

The following DIMM has

establish a successful data link with

on page 102.

been disabled by BIOS:

the memory controller.

 

DIMM x

 

 

 

 

 

PCIe Degraded Link Width

Faulty or improperly installed PCIe

Reseat the PCIe card in the specified

Error: Embedded

card in the specified slot.

slot number. See "Expansion-Card Riser"

Bus#nn/Dev#nn/Funcn

 

on page 81. If the problem persists, see

Expected Link Width is n

 

"Getting Help" on page 125.

 

 

Actual Link Width is n

 

 

 

 

 

PCIe Degraded Link Width

Faulty or improperly installed PCIe

Reseat the PCIe card in the specified

Error: Slot n

card in the specified slot.

slot number. See "Expansion-Card Riser"

Expected Link Width is n

 

on page 81. If the problem persists, see

 

"Getting Help" on page 125.

Actual Link Width is n

 

 

 

 

 

 

PCIe Training Error:

Faulty or improperly installed PCIe

Reseat the PCIe card in the specified

Embedded

card in the specified slot.

slot number. See "Expansion-Card Riser"

Bus#nn/Dev#nn/Funcn

 

on page 81. If the problem persists, see

PCIe Training Error:

 

"Getting Help" on page 125.

 

 

Slot n

 

 

 

 

 

PCI BIOS failed to install

PCI device BIOS (Option ROM)

Reseat the expansion card(s). Ensure

 

checksum failure is detected during

that all appropriate cables are securely

 

shadowing.

connected to the expansion card(s). If

 

Loose cables to expansion card(s);

the problem persists, see

 

"Troubleshooting Expansion Cards" on

 

faulty or improperly installed

 

page 107.

 

expansion card(s).

 

 

 

 

 

Plug & Play Configuration

Error encountered in initializing PCI

Install the NVRAM_CLR jumper and

Error

device; faulty system board.

reboot the system. See Figure 6-1 for

 

 

jumper location. If the problem persists,

 

 

see "Troubleshooting Expansion Cards"

 

 

on page 107.

28

About Your System

Page 28
Image 28
Dell 1950 No boot sector on hard, Drive, No timer tick interrupt, Northbound merge error, Following Dimm has, Error Slot n