System Messages
System messages appear on the screen to notify you of a possible problem with the system.
NOTE: If you receive a system message not listed in the table, check the documentation for the application that is running when the message appears or the operating system's documentation for an explanation of the message and recommended action.
Message | Causes | Corrective Actions |
|
|
|
Alert! iDRAC6 | The optional iDRAC6 is not | Wait for the system to |
not responding. | responding to BIOS | reboot. |
Rebooting. | communication either |
|
| because it is not functioning |
|
| properly or has not |
|
| completed initialization. The |
|
| system will reboot. |
|
Alert! iDRAC6 not responding. Power required may exceed PSU wattage.
Alert! Continuing system boot accepts the risk that system may power down without warning.
The optional iDRAC6 is hung.
The optional iDRAC6 was remotely reset while system was booting.
After AC recovery, the iDRAC6 takes longer than normal to boot.
Remove AC power to the system for 10 seconds and restart the system.
Alert! | The system configuration of |
Continuing | processor, memory modules, |
system boot | and expansion card may not |
accepts the risk | be supported by the power |
that system may | supply. |
power down |
|
without warning. |
|
If any system components were just upgraded, return the system to the previous configuration. If the system boots without this warning, then the replaced component(s) are not supported with this power supply. See "Power Supply" on page 97.