Message

Causes

Corrective Actions

 

 

 

The following

Invalid memory

Ensure that the memory

DIMMs should

configuration. The specified

modules are installed in a

match in

memory modules do not

valid configuration. See

geometry:

match in size, number of

"General Memory Module

x,x,...

ranks, or number of data

Installation Guidelines" on

The following

lanes.

page 79.

 

 

DIMMs should

 

 

match in rank

 

 

count: x,x,...

 

 

The following

 

 

DIMMs should

 

 

match in size:

 

 

x,x,...

 

 

The following

 

 

DIMMs should

 

 

match in size

 

 

and geometry:

 

 

x,x,...

 

 

The following

 

 

DIMMs should

 

 

match in size

 

 

and rank count:

 

 

x,x,...

 

 

 

 

 

Thermal sensor

A memory module without a

Replace the memory

not detected

thermal sensor is installed in

module. "System Memory"

on x.

the specified memory slot.

on page 79.

 

 

 

Time-of-day

Faulty battery or faulty chip.

See "Troubleshooting the

clock stopped.

 

System Battery" on page 114.

 

 

 

Time-of-day not

Incorrect Time or Date

Check the Time and Date

set - please run

settings; faulty system

settings. See "Using the

SETUP program.

battery.

System Setup Program and

 

 

UEFI Boot Manager" on

 

 

page 37. If the problem

 

 

persists, replace the system

 

 

battery. See "System Battery"

 

 

on page 99.