Message

Causes

Corrective Actions

 

 

 

No boot sector on

Incorrect configuration

Check the hard-drive

hard drive.

settings in System Setup

configuration settings in the

 

program, or no operating

System Setup program. See

 

system on hard drive.

"Using the System Setup

 

 

Program and UEFI Boot

 

 

Manager" on page 37. If

 

 

necessary, install the

 

 

operating system on your

 

 

hard drive. See your

 

 

operating system

 

 

documentation.

 

 

 

No timer tick

Faulty system board.

See "Getting Help" on

interrupt.

 

page 133.

 

 

 

PCI BIOS failed

PCIe device BIOS (Option

Reseat the expansion card.

to install.

ROM) checksum failure

Ensure that all appropriate

 

detected during shadowing.

cables are securely connected

 

Cables to expansion card

to the expansion card. If the

 

problem persists, see

 

loose; faulty or improperly

 

"Troubleshooting an

 

installed expansion card.

 

Expansion Card" on

 

 

 

 

page 121.

PCIe Training Error: Expected Link Width is x, Actual Link Width is y.

Faulty or improperly installed PCIe card in the specified slot.

Reseat the PCIe card in the specified slot number. See "Troubleshooting an Expansion Card" on

page 121. If the problem persists, see "Getting Help" on page 133.

Plug &

Play

Error encountered in

Configuration

initializing PCIe device;

Error.

 

faulty system board.

Install the NVRAM_CLR jumper in the clear position (pins 1 and 3) and reboot the system. See Figure 6-1 for jumper location. If the problem persists, see "Troubleshooting an Expansion Card" on

page 121.

About Your System

27

Page 25
Image 25
Dell R210 owner manual No boot sector on