Message

Causes

Corrective Actions

 

 

 

Memory set to

The memory frequency may

If not an intentional setting,

minimum

be intentionally set lower for

check any other system

frequency.

power conservation.

messages for possible causes.

 

The current memory

Ensure that your memory

 

configuration may support

configuration supports the

 

only the minimum

higher frequency. See

 

frequency.

"General Memory Module

 

 

Installation Guidelines" on

 

 

page 79.

 

 

 

Memory tests

POST memory test was

Information only.

terminated by

terminated by pressing the

 

keystroke.

spacebar.

 

 

 

 

MEMTEST lane

Invalid memory

Ensure that the memory

failure

configuration. A mismatched

modules are installed in a

detected on x.

memory module is installed.

valid configuration. See

 

 

"General Memory Module

 

 

Installation Guidelines" on

 

 

page 79.

No boot device

Faulty or missing optical

available.

drive subsystem, hard drive,

 

or hard-drive subsystem, or

 

no bootable USB key

 

installed.

Use a bootable USB key, CD, or hard drive. If the problem persists, see "Troubleshooting a USB Device" on page 110, "Troubleshooting an Optical Drive" on page 119, and "Troubleshooting a Hard Drive" on page 120. See "Using the System Setup Program and UEFI Boot Manager" on page 37 for information on setting the order of boot devices.

26

About Your System

Page 24
Image 24
Dell R210 owner manual Memtest lane