Physical
For temperatures between 40°C and 45°C, de- rate maximum allowable temperature by 1°C per 125 m above 950 m (1°F per 228 ft).
Expanded Operating Temperature Restrictions • Do not perform a cold startup below 5°C.
• The operating temperature specified is for a maximum altitude of 3050 m (10,000 ft).
• 160 W (10 core) processor is not supported.
• Tape Backup Unit (TBU) is not supported.
• Redundant power supplies are required.
• Non Dell qualified peripheral cards and/or peripheral cards greater than 25 W are not supported.
• PCIe SSD and GPU is not supported.
• Maximum 120 W processor supported on 3.5 inch hard drive chassis.
• Maximum 145 W processor supported on 2.5 inch hard drive chassis.
• Only SSDs are allowed in the hard drive slots at the back of the 3.5 inch hard drive chassis.
155