Image 60

NOTE: 1R, 2R, and 4R in the following tables indicate single-, dual-, and quad-rank DIMMs respectively.

Table 26. Memory configurations—two processors

System

DIMM size (in

Number of

DIMM rank,

DIMM slot population

capacity (in

GB)

DIMMs

organization, and

 

GB)

 

 

frequency

 

 

 

 

 

 

64

16

4

2R, x4, 2133 MT/s,

A1, A2, B1, B2

 

 

 

2R, x4, 1866 MT/s,

 

128

16

8

2R, x4, 2133 MT/s,

A1, A2, A3, A4, B1, B2, B3, B4

 

 

 

2R, x4, 1866 MT/s,

 

256

16

16

2R, x4, 2133 MT/s,

A1, A2, A3, A4, A5, A6, A7, A8,

 

 

 

2R, x4, 1866 MT/s,

B1, B2, B3, B4, B5, B6, B7, B8

 

 

 

 

384

16

24

2R, x4, 2133 MT/s,

A1, A2, A3, A4, A5, A6, A7, A8,

 

 

 

 

A9, A10, A11, A12, B1, B2, B3, B4,

 

 

 

2R, x4, 1866 MT/s,

B5, B6, B7, B8, B9, B10, B11, B12

512

32

16

LRDIMM, 4R, x4, 2133

A1, A2, A3, A4, A5, A6, A7, A8,

 

 

 

MT/s

B1, B2, B3, B4, B5, B6, B7, B8

768

32

24

LRDIMM, 4R, x4, 1866

A1, A2, A3, A4, A5, A6, A7, A8,

 

 

 

MT/s

A9, A10, A11, A12, B1, B2, B3, B4,

 

 

 

LRDIMM, 4R, x4, 1600

B5, B6, B7, B8, B9, B10, B11, B12

 

 

 

 

 

 

 

MT/s

 

Removing memory modules

Prerequisites

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

1.Ensure that you read the Safety instructions.

2.Follow the procedure listed in Before working inside your system.

3.Remove the cooling shroud.

4.If installed, remove the cooling-fan assembly. For more information, see Removing the cooling-fan assembly

WARNING: The memory modules are hot to touch for some time after the system has been powered down. Allow the memory modules to cool before handling them. Handle the memory modules by the card edges and avoid touching the components or metallic contacts on the memory module.