Table 26. Memory
System | DIMM size (in | Number of | DIMM rank, | DIMM slot population |
capacity (in | GB) | DIMMs | organization, and |
|
GB) |
|
| frequency |
|
|
|
|
|
|
64 | 16 | 4 | 2R, x4, 2133 MT/s, | A1, A2, B1, B2 |
|
|
| 2R, x4, 1866 MT/s, |
|
128 | 16 | 8 | 2R, x4, 2133 MT/s, | A1, A2, A3, A4, B1, B2, B3, B4 |
|
|
| 2R, x4, 1866 MT/s, |
|
256 | 16 | 16 | 2R, x4, 2133 MT/s, | A1, A2, A3, A4, A5, A6, A7, A8, |
|
|
| 2R, x4, 1866 MT/s, | B1, B2, B3, B4, B5, B6, B7, B8 |
|
|
|
| |
384 | 16 | 24 | 2R, x4, 2133 MT/s, | A1, A2, A3, A4, A5, A6, A7, A8, |
|
|
|
| A9, A10, A11, A12, B1, B2, B3, B4, |
|
|
| 2R, x4, 1866 MT/s, | B5, B6, B7, B8, B9, B10, B11, B12 |
512 | 32 | 16 | LRDIMM, 4R, x4, 2133 | A1, A2, A3, A4, A5, A6, A7, A8, |
|
|
| MT/s | B1, B2, B3, B4, B5, B6, B7, B8 |
768 | 32 | 24 | LRDIMM, 4R, x4, 1866 | A1, A2, A3, A4, A5, A6, A7, A8, |
|
|
| MT/s | A9, A10, A11, A12, B1, B2, B3, B4, |
|
|
| LRDIMM, 4R, x4, 1600 | B5, B6, B7, B8, B9, B10, B11, B12 |
|
|
|
| |
|
|
| MT/s |
|
Removing memory modules
Prerequisites
CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
1.Ensure that you read the Safety instructions.
2.Follow the procedure listed in Before working inside your system.
3.Remove the cooling shroud.
4.If installed, remove the
WARNING: The memory modules are hot to touch for some time after the system has been powered down. Allow the memory modules to cool before handling them. Handle the memory modules by the card edges and avoid touching the components or metallic contacts on the memory module.