Dell XC730xd owner manual Removing a DC power supply unit, Required wires

Models: XC730xd

1 157
Download 157 pages 55.24 Kb
Page 104
Image 104

Required wires

One UL 10 AWG, 2 m maximum (stranded) black wire [–(48–60) V DC]

One UL 10 AWG, 2 m maximum (stranded) red wire (V DC return)

One UL 10 AWG, 2 m maximum green/yellow, green with a yellow stripe, stranded wire (safety ground)

Removing a DC power supply unit

Prerequisites

WARNING: For equipment using –(48–60) V DC power supplies, a qualified electrician must perform all connections to DC power and to safety grounds. Do not attempt connecting to DC power or installing grounds yourself. All electrical wiring must comply with applicable local or national codes and practices. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow all safety instructions that came with the product.

CAUTION: The system requires one power supply for normal operation. On power-redundant systems, remove and replace only one power supply at a time in a system that is powered on.

NOTE: You may have to unlatch and lift the optional cable management arm if it interferes with power supply removal. For information about the cable management arm, see the system’s rack documentation.

Steps

1.Disconnect the power wires from the power source and the connector from the power supply you intend to remove.

2.Disconnect the safety ground wire.

3.Press the release latch and slide the power supply out of the chassis.

Figure 47. Removing and installing a DC power supply

1. release latch

2. power supply status indicator

104

Page 104