7.To configure this user for outbound connections, enter the following command:

set user name=name outgoing=on device=device

where device is either the Digi-supplied device or the outbound device created earlier in this procedure

Example:

set user name=pppout outgoing=on device=gendialer

8.To configure an IP address for the local end of the PPP connection, enter the following command:

set user name=name localipaddr=ip-address

where name is the user’s name and ip-addressis one of the following:

0.0.0.0. , which means that the user will request an IP address from the remote server.

A specific IP address, which means that the Digi device will attempt to use this IP address. The remote server must agree to this request.

Example: set user name=pppout localipadr=0.0.0.0

9.To configure a telephone number to dial to reach the outbound user, enter the following command:

set user name=name n1=telephone-number

where name is the user’s name and telephone-numberis the number to dial to reach the user. You can enter this number as digits only, with dashes (-) separating digits, or with commas.

Example: set user name=pppout n1=4452624

Sample

The following sample shows a very simple outbound PPP configuration. Here are some points on this configuration:

The port is set up for outbound connections (dev=mout).

Flow control is set to Hardware.

Default device and scripts are used

set ports range=3 device=mout

set flow range=3 ixon=off ixoff=off rts=on cts=on set line range=3 baud=115000

set user name=pppout protocol=ppp

set user name=pppout dialout=on outgoing=on device=gendialer set user name=pppout localipadr=0.0.0.0

set user name=pppout n1=4452624

30

Chapter 8 Configuring PPP

Page 30
Image 30
Digi W manual Sample