Device Server EIA 232/422/485 Switch Settings

Function

 

 

Switch Settings

 

 

 

 

 

1

2

 

3

4

 

 

 

 

 

 

 

 

EIA-232

Up

Down

 

Down

Down

 

 

 

 

 

 

EIA-422/485 Full-duplex

Down

Up

 

Down

If up, termination.

 

 

 

 

 

If down,

EIA-485 half-duplex

Down

Down

 

Up

 

no termination

 

 

 

 

 

 

RJ-45 Pinouts

RJ-45

EIA-232

EIA-422/485

EIA-485 Half-

Pin

Full-Duplex

Duplex

 

 

 

 

 

1

RI

TxD-

TxD-

 

 

 

 

2

DSR

RxD-

RxD-

 

 

 

 

3

RTS

RTS+

NA

 

 

 

 

4

GND

GND

GND

 

 

 

 

5

TxD

TxD+

TxD+

 

 

 

 

6

RxD

RxD+

RxD+

 

 

 

 

7

SG

SG

SG

 

 

 

 

8

CTS

CTS+

NA

 

 

 

 

9

DTR

RTS-

NA

 

 

 

 

10

DCD

CTS-

NA

 

 

 

 