Digi W manual Configuring DTR Power

Models: W

1 84
Download 84 pages 28.08 Kb
Page 76
Image 76

2. Close the device unit enclosure.

RI Power Out

Ring Indicator (RI) power out is available on all ports. The total power budget for this feature is one (1) watt not to exceed 5 volts @ up to 200mA on any single port. The following procedure assumes the unit will only be used for RI power out.

1.Set the port DIP switches to the following places: switch 1 and 3 are up and 2 and 4 are down (see "Serial Power Table" on page 77 for illustration).

2.Enable the RI power through the web interface.

3.Connect power supply with the barrel-connector power supply provided with the device or use powered Ethernet.

Note: If the unit will be used with RI power in (port 1 only), set the jumper to the following setting:

P-6 jumper on pins 1and 2

and do not use an external power source. Port 1 cannot be used for both power in and power out.

Configuring DTR Power

Power Out

Data Terminal Ready (DTR) power out is the factory default on the Digi device server. Total power budget for this feature is one watt not to exceed 9 volts @ up to 100mA to any single port.

1.Set the port DIP switches to EIA 232 (switch 1 is up, 2,3, and 4 are down) to enable DTR power.

2.Open the port and set DTR high.

Note Here are the pins to verify the jumper position. The default position has the jumper on the two pins furthest from the edge.

DO NOT MOVE THE

JUMPER FROM THE

DEFAULT UNLESS USING RI POWER IN.

If you are having trouble with your unit after using the Power over port feature, you may have tripped the circuit breaker in the unit. You can identify this by the RI or DTR signal indicators found in the System Information under Administration on the main menu in the web interface. Click the port number using serial power. (Remember serial power out is unavailable if the MEI settings are not 232.)

Under serial power will be a message if the breaker is tripped. Follow the

76

Chapter 18 Configuring Power Over the Serial Ports

Page 76
Image 76
Digi W manual Configuring DTR Power