Data Set Ready (DSR) and Clear to Send (CTS) may be used by the host to verify controller connections and operation. DSR is asserted when power is applied to the controller and CTS is asserted when the controller's power-on sequence is complete. Data Terminal Ready (DTR) and Request to Send (RTS) can also be connected for full hardware handshaking.

Elo driver software typically requires two-way communication and all four handshaking lines.

If accessible, the controller's diagnostic LED can verify whether RS-232 data is being transmitted.

Alternatively, a breakout box will tell you if there is any activity on the data line. It is possible that the port you are using on the host computer is meant to work with an RS-232 DTE device. To check this, install a null modem cable between the controller and the host computer's serial port. A null modem cable converts a DCE device into a DTE device by swapping pins 2 and 3 and the handshaking lines.

Some serial ports require jumpers for the handshaking lines on the cable connector at the computer end. The jumper combinations that may be required to make an RS-232 port work are beyond the scope of this manual. Consult your computer manual for more information.

If a breakout box is not available, you can measure the DC voltage at the data output of the controller (pin 2 of the DB-9). It should measure between 8 and 10 Vdc when the touchscreen is not touched, and drop several volts (towards 0) during a touch, depending on the data format and the baud rate.

If proper RS-232 signal voltage is not present, the controller may not have power applied.

Power Connections

Check for proper voltage (+5 Vdc) at the power connector P4 pin 1 (+) and pin 4 (-) on the controller (see, page). If the LED is functioning (see page Diagnostic LED’s), the power supply is probably okay. To access this connector on the external serial controller, disconnect the power, then remove the cover. Reconnect the power cable and turn the unit on. There are no exposed electrical connections in the controller that would be considered dangerous. Power is applied to the controller through P4.

If no power is present, measure the voltage at the power source, either a source from the display electronics, a DC-to-DC converter, or an AC power supply.

A-55

Page 67
Image 67
Elo TouchSystems IntelliTouch SecureTouch manual Power Connections