Elo TouchSystems IntelliTouch SecureTouch manual Jumper Settings, Jumper Function

Models: IntelliTouch SecureTouch

1 105
Download 105 pages 32.75 Kb
Page 87
Image 87

Table B.7 Power connector, P4, pins and signal names

Signal name

P4 pin

Signal function

 

 

 

+Regulated Pwr

1

+5 volts DC +/- 5%

Pwr Com

2

Supply voltage common

reserved

3

no connection allowed

Pwr Com

4

Supply voltage common

LED Remote1

5

 

n/c

6

key location

n/c

7

 

Frame ground

8

 

-Reset

9

Open = normal operation

 

 

short to Pwr com = hardware reset.

reserved

10

no connection allowed

1. Source impedance is 500 ohms to Vcc. Current drive available for typical LED is 6mA.

Jumper Settings

Table B.8 Jumper Locations and function if installed

Jumper

Function

 

 

J1

Set NVRAM to defaults on power

 

up

J2

Emulation Mode = E281A-4002

 

 

The 2500S is shipped with a single jumper fitted to not enable either J1 or J2. Consult the drawings later in this document for the position of the jumpers.

LED Diagnostic Characteristics

A green LED indicates controller status as follows:

LED Blink Rate

Function

 

 

Once per second

Normal condition, untouched state

On continuously

Touched state

Twice per second

Error detected

 

 

B-75

Page 87
Image 87
Elo TouchSystems IntelliTouch SecureTouch manual Jumper Settings, Jumper Function