Everpure 325 manual Cold Drink Center 327/328 Operator’s Guide, Hydrolife Filter Installation

Models: 325 327

1 88
Download 88 pages 807 b
Page 12
Image 12
HYDROLIFE FILTER INSTALLATION

Cold Drink Center (327/328) Operator’s Guide

HYDROLIFE FILTER INSTALLATION

a.Place the filter inside the canister. Be sure the o-ring is seated in the canister just below the threads.

b.Screw the canister and filter assembly onto the filter head until it comes to a stop.

c.Open the water valve on the inlet line by rotating the handle to the verti- cal position as shown.

HYDROLIFE FILTER REMOVAL

a.Close the valve on the inlet line by rotating the handle into the horizontal position as shown.

b.Relieve water pressure by performing two or three water throws (See "Test Throw Still Water" on page 64).

c.Unscrew the filter and canister assembly from the filter head. Remove the filter from the canister.

August, 2003

Page 6

3280020

Page 12
Image 12
Everpure 325 manual Cold Drink Center 327/328 Operator’s Guide, Hydrolife Filter Installation, Hydrolife Filter Removal