VIEW SUREVEND™ AVERAGE CALIBRATION VALUE
2. CONTINUE.

Cold Drink Center (327/328) Operator’s Guide

On input screen #2, you can press the following letters to perform the indicated operation:

ADispense ice (and turn on the icemaker compressor if the hop- per is not full)

BForce CO2 valve on

CDispense carbonated water

DDispense still water

5.Actuate each switch or sensor to test its function. As you actuate each input, the display element representing that switch blinks on. Releasing the switch causes that element to blink off again.

6.CONTINUE.

VIEW SUREVEND™ AVERAGE CALIBRATION VALUE

1. Press CAL.AVEXXXManual background , then press Manual background until the display shows.

2. CONTINUE.

 

CAL.AVEXXX

 

 

 

3280020

Page 69

August, 2003

XXX represents the average sensor calibration value (should be between 50 and 255 for proper sensor operation - i.e. 51 through 254). Although this number could go as low as 20, the SureVend™ system will be inoperative in this condition.

VIEW SUREVEND™ LAST RECORDED CALIBRATION VALUE

1. Press Manual backgroundManual background , then press until the display shows.

XXX can be any number from 0 to 255, and represents theCALmost.LSTrecentXXX value read from the sensor. The lower the number, the greater the sensor

blockage. A number of 255 means that there is a fatal problem with the SureVend™ interface board. Ensure the SureVend™ interface PCB is properly connected to the main controller PCB.

Page 75
Image 75
Everpure 325 manual Cold Drink Center 327/328 Operator’s Guide, Cal.Avexxx, View Surevend Average Calibration Value