Cold Drink Center (327/328) Operator’s Guide
3.Testing the water pump flow
The water pump should require between 13 and 21 seconds to completely refill the carbonator. To check the water flow, proceed as follows:
a. Place a cup in the cup station and make sure the waste pail is in place.
b. | Press | , then | until the display shows: | . | |
c. | Press | . The water pump starts, and the display shows | |||
| while the carbonator dispenses, then shows |
| as the carbonatorbjmqvfkd= | ||
| refills. |
|
|
|
|
d. | After adjusting the flow, repeat step c until the desired time is achieved. | ||||
4. Adjusting the water pump flow: |
|
|
| ||
a. | Remove the cap nut to expose the adjustment screw. | ||||
b. | Turn the adjustment screw: |
|
|
| |
| CLOCKWISE to decrease refill time. |
|
| ||
| COUNTERCLOCKWISE to increase refill time. |
| |||
|
|
| NOTE |
|
|
| Failure to replace the cap nut will cause the water pump to leak. | ||||
c. | Replace the cap nut. |
| cfii=uu | `^o_=qbpq | |
|
| WATER |
| ||
|
| PUMP |
| ||
|
| CAP |
|
| |
|
| NUT |
|
|
ADJUSTING
SCREW
5.Adjusting the water valve:
The water valves are located under the water bath cover.
NOTE
To prevent personal injury, only turn the adjusting screw when making adjustments. DO NOT loosen or remove the limit screw located above the adjusting screw.
NOTE
See "Set Up A Drink" on page 36, for the procedure and table for setting throws.
3280020 | Page 13 | August, 2003 |