Image 78
SV.ERR

Cold Drink Center (327/328) Operator’s Guide

 

PCB

SureVend™ is ON but not working. The last calibration sam-

 

NOTE

 

 

ple was 255. Check that the SureVend™ PCB is present at

SV.ERR

 

J34.

 

 

SureVend™ is ON but not working. The last calibration sam-

 

 

ple was 50. Check for a blocked sensor or disconnected har-

 

 

ness.

 

1

SureVend™ is active and ring 1 anti-jackpot timer is ON. XX is

AJP.TMRXX

a value between 1 and 99 in minutes.

SureVend™ is active and ring 2 anti-jackpot timer is ON. XX is a value between 1 and 99 in minutes, and represents the amount of time left on the anti-jackpot timer for this cup ring.

DOWNLOAD DATA TO A PDCD

1.

Connect your portable data collection device (PDCD) in accordance with its

 

operating instructions.

 

2.

Press

. The display shows

while data is being

 

downloaded into your PDCD.

 

 

 

Depending upon the setting selected in "Set Printer or DEX

 

 

Mode" on page 25, data may be cleared after the download is

 

 

SNSR

 

complete.

 

3.

If there is a problem with your PDCD or its connection, several beeps sound

 

and the error message

 

appears briefly. Check your PDCD,

 

connections, or consult your PDCD user’s manual.

 

4.

CONTINUE.2

 

DEXMODE

 

 

ABORTT.O.

 

August, 2003

Page 72

3280020