Environmental Monitoring Unit

Table 3-3 Power Sequencing Signals

 

 

 

 

 

SW5

 

SW6

Action

 

Off

 

Off

No delayed power sequencing

 

On

 

Off

Power sequencing if only 1 PSU is available

 

X

 

On

Delayed power sequencing

 

X = Don’t Care

 

 

 

SW7 enables SCSI Termination power for bus one and SW8 enables SCSI Termination power for bus two.

Available EMU information

More comprehensive information is provided to intelligent agents such as Eurologic’s Vision software. Configuration, warning and status Information is available from all EMU’s. The single EMU Storage System will provide the data shown in Table 3-4 and Table 3-5.

Table 3-4 Read Only Memory locations within the EMU

Data Name

Number of Information Bytes

EMU Part No.

4 bytes

EMU Firmware Rev

2 bytes

EMU Serial No.

4 bytes

EMU Power Cycle Count

2 bytes

Status Byte

2 bytes

EMU Available

2 bytes

EMU Attention

2 bytes

Local Temp

2 bytes

EMU Data

8 bytes

Fan Insertion Count

2 bytes per Fan

PSU Insertion Count

2 bytes per PSU

SCSI Device Insertion Count

2 bytes per SCSI Devices

Table 3-5 Read/Write locations within the EMU

Data Name

Number of Information Bytes

Master

12 bytes

Alarm Temperature

2 bytes

Critical Temperature

2 bytes

Action Byte

2 bytes

SCSI Device Status

2 bytes

Power Supply Control & Status

2 bytes

Fan Status

2 bytes

3-5

Page 39
Image 39
First Virtual Communications 3000 user manual Available EMU information, Power Sequencing Signals, SW5 SW6