14.(00001110) Phase 1 - Pump Connection Fault

The Display Module has detected that the pump is not on when it should be.

Primary Source - Pump

Action

1.The pump is fitted with a thermal cut out device. Check if this device has been activated. If the device is activated wait until pump cools down before restarting. Check for any pump blockage and check condition of pump (pump seizure).

2.Check for open circuit pump windings. Check the resistance of the pump.

3.Check the pump harness or the connectors for an open circuit.

4.Replace Display Module.

15.(00001111) Phase 1 - Display Module Fault

The Display Module has read an incorrect voltage on the pump circuit.

Primary Source - Display Module

Action - Replace Display Module. NB. If Smartdrive is running at well below it's rated supply voltage and the pump has operated for more than 4 seconds at this voltage this fault will also appear.

17 – 20. (00010xxx) Phase 1 - Display / Motor Controller Out of Sequence 22 - 23. (000101xx) Phase 1 - Display / Motor Controller Out of Sequence

The Display Module and Motor Controller are running out of sequence.

Primary Source

Action

Turn off Smartdrive at the wall and back on again after 5 seconds. Re-start.

If fault persists disable auto restart feature and retest. A new fault code will appear. Carry out action of new fault details.

25.(00011001) Phase 5 IW – LCD Initialisation Error

The intuitive display has detected a problem with the LCD.

Primary Source – IW Display Module

Action - Replace IW Display Module

28 – 30. (000111xx) Phase 1 - Display / Motor Controller out of Sequence

Refer to fault code 17