164.(10100100) Phase 4 to 5 - Brake Function Time-out Fault

This fault indicates that the Motor Controller has been attempting to brake for 20 seconds. All spin loads should come to rest within 10 seconds something must have gone wrong during the brake to prevent the bowl stopping in time.

Primary Source - Wiring

Action - Measure/check the motor harness, connectors and motor for discontinuity. This can be done by taking a resistance measurement between phases of the motor harness at the Motor Controller.

Secondary Source - Motor Controller (Phase 4). Rotor Position Sensor (Phase 5) Action - Replace Motor Controller (Phase 4). Rotor Position Sensor (Phase 5)

192.(11000000) Phase 4 to 5 – Motor Controller Fault

The Motor Controller has internally sensed a connection is open circuit. The motor cannot be operated with this condition.

Primary Source - Motor Controller Action - Replace Motor Controller.