Fisher & Paykel 517735 service manual Option Adjustment Mode for IW, Pump

Models: 517735

1 92
Download 92 pages 53.84 Kb
Page 88
Image 88

RECIRCULATING VALVE

PUMP

The pump is the same as Phase 5. The pump forms part of the power supply. If it not connected Smartdrive will appear to have no power. The pump resistance is 33 ohms.

E.4 OPTION ADJUSTMENT MODE for IW

In Option Adjustment Mode the following adjustments may be made: -

The fill level selected by Auto Water Level. The type of rinse.

The temperature of the wash. The spin speed for Creasables.

The recovery routine selected when a load goes out of balance. The number of beeps at the end of the cycle.

Adjust Options Menu

auto

water

temp

auto

rinse

other

With Smartdrive powered on push the OPTIONS button and hold down for 4 seconds. The Adjust Options Menu will be displayed. Push the small button next to the option to be adjusted. The display will change to the choices available for that option. To set the option push the small button next to it. The display screen will highlight the selection before returning to the main screen.

- 83 -

Page 88
Image 88
Fisher & Paykel 517735 service manual Option Adjustment Mode for IW, Pump