9.0 SIZE SETTING MODE – Phase 4 and 5 only

Phase 1-3sizes are determined by 2 switches on the display and protrusions on the console. When replacing Display or Motor Controller enter Option Adjustment mode to set these sizes in EEPROM. To check the size setting on Phase 1-3 use DIAGNOSTIC mode. See section 8.2. Size setting mode is required for Phase 1 spare (426518 Motor Controller and 426433 Display). For IW see service manual Appendix E..

It is important to set the size switch setting into the Motor Controller’s memory whenever a replacement Motor Controller or Display Module is fitted to Smartdrive. Failure to do this will result in Smartdrive faulting with fault code 9.

Accessing size setting mode is the best way to check the size for Phase 4 & 5 and Phase 1 spare. The size setting of Smartdrive may be checked in Diagnostic mode for all phases.

To set the size switch turn the power on at the power point and off at the console. Press and hold the TEMPERATURE UP button then press the POWER button. Smartdrive will give 4 short beeps and the pattern of LEDs will change.

Press TEMPERATURE UP button, the COLD LED is on for 5-5.5kg(560mm wide).

Press WATER LEVEL UP button, the LOW WATER LED is on for 6-6.5kg(600mm wide).

Press SPIN SPEED UP button, the SPIN HOLD LED is on for 7-7.5kg(650mm wide).

Press POWER to exit this mode.

SIZE SWITCH SET UP

MODE

 

 

RINSE

FINAL SPIN

 

 

 

 

RINSE

 

 

 

 

 

 

ADVANCE

5- 5.5kg

6.5kg

7.5kg

O FAST

 

 

 

O HOT

O HIGH O

MED

 

 

 

O WARM O MED O

SLOW

POWER

 

 

 

 

 

O COLD O LOW O

HOLD

 

PRESS TEMP UP &

 

5.kg

 

 

 

POWER TO ENTER

5.5kg

6.5kg

7.5kg

START

SIZE

SIZE

THIS MODE

SIZE

PAUSE

 

 

 

 

 

 

 

 

DELAY

 

 

 

 

START

 

WASH

WATER

SPIN

 

 

TEMP

LEVEL

SPEED

 

 

 

 

 

LED on

 

 

 

 

LED off

If the size is set incorrectly Smartdrive will have the following settings incorrect: -

The Auto Water Levels chosen by Smartdrive may be wrong.

The High Water Level may be wrong by as much as 40mm.

The flow rate for inlet water, normally 3 litres per minute, may be set incorrectly.

The wash profile controls the strength of the agitator. This could result in poor wash performance or splashing.

Water saver settings.